Repositori DSpace/Manakin

A new estimator to minimize the error due to breathing in the measurement of respiratory impedance

Mostra el registre parcial de l'element

dc.creator Navajas Navarro, Daniel
dc.creator Farré Ventura, Ramon
dc.creator Rotger i Estapé, Maria del Mar
dc.creator Peslin, René
dc.date 2009-06-17T08:40:18Z
dc.date 2009-06-17T08:40:18Z
dc.date 1988
dc.date.accessioned 2024-12-16T10:18:05Z
dc.date.available 2024-12-16T10:18:05Z
dc.identifier 0018-9294
dc.identifier http://hdl.handle.net/2445/8686
dc.identifier 35251
dc.identifier.uri http://fima-docencia.ub.edu:8080/xmlui/handle/123456789/7083
dc.description This paper presents a new respiratory impedance estimator to minimize the error due to breathing. Its practical reliability was evaluated in a simulation using realistic signals. These signals were generated by superposing pressure and flow records obtained in two conditions: 1) when applying forced oscillation to a resistance- inertance- elastance (RIE) mechanical model; 2) when healthy subjects breathed through the unexcited forced oscillation generator. Impedances computed (4-32 Hz) from the simulated signals with the new estimator resulted in a mean value which was scarcely biased by the added breathing (errors less than 1 percent in the mean R, I , and E ) and had a small variability (coefficients of variation of R, I, and E of 1.3, 3.5, and 9.6 percent, respectively). Our results suggest that the proposed estimator reduces the error in measurement of respiratory impedance without appreciable extracomputational cost.
dc.format 5 p.
dc.format application/pdf
dc.language eng
dc.publisher IEEE
dc.relation Reproducció del document publicat a http://dx.doi.org/10.1109/10.8684
dc.relation IEEE Transactions on Biomedical Engineering, 1988, vol. 35, núm. 12, p. 1001-1005.
dc.relation http://dx.doi.org/10.1109/10.8684
dc.rights (c) IEEE, 1988
dc.rights info:eu-repo/semantics/openAccess
dc.source Articles publicats en revistes (Ciències Fisiològiques)
dc.subject Errors científics
dc.subject Mesurament
dc.subject Biomedical measurement
dc.subject Measurement errors
dc.subject Pneumodynamics
dc.title A new estimator to minimize the error due to breathing in the measurement of respiratory impedance
dc.type info:eu-repo/semantics/article
dc.type info:eu-repo/semantics/publishedVersion


Fitxers en aquest element

Fitxers Grandària Format Visualització

No hi ha fitxers associats a aquest element.

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a DSpace


Cerca avançada

Visualitza

El meu compte