Repositori DSpace/Manakin

Separation and characterization of microRNAs by capillary electrophoresis with ultraviolet detection and mass spectrometry

Mostra el registre parcial de l'element

dc.contributor Benavente Moreno, Fernando J. (Julián)
dc.creator Martín Gonzàlez, Abel
dc.date 2019-02-25T14:58:20Z
dc.date 2019-02-25T14:58:20Z
dc.date 2019-01
dc.date.accessioned 2024-12-16T10:27:18Z
dc.date.available 2024-12-16T10:27:18Z
dc.identifier http://hdl.handle.net/2445/128823
dc.identifier.uri http://fima-docencia.ub.edu:8080/xmlui/handle/123456789/22223
dc.description Treballs Finals de Grau de Química, Facultat de Química, Universitat de Barcelona, Any: 2019, Tutor: Fernando Benavente
dc.description MicroRNAs (miRNA) are a class of small endogenous RNA molecules of about 19-23 nucleotides that act as regulators of genes. Aberrant expression of these oligonucleotides has been associated with a plethora of diseases ranging from nervous system diseases, heart diseases, inherited diseases and different types of cancer. The increasing association between miRNA malfunction and diseases coupled with the advances in detection and characterization of these kinds of analytes have turned miRNAs into an interesting topic of study, especially within the molecular biology field. Due to their stability towards pH, temperature and other factors, applications of microRNAs in forensic studies have also been studied. In this work we have optimized a capillary electrophoresis with ultraviolet detection method (CE-UV) that allows separating a mixture of synthetic miRNAs with similar nucleotide sequence and length. Compatibility with on-line mass spectrometry detection was also considered during the optimization. The method was validated in terms of repeatability of migration times and peak heights, linearity and limits of detection (LOD). For characterization of miRNAs matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was used, where mass accuracy and other quality parameters were evaluated and compared between different modes. Better LOD than the CE-UV method and good mass accuracy were achieved using one of the miRNAs as an internal standard for the calibration, though loss of repeatability of peak area and height was observed, making this method unsuitable for quantitative analysis. Sequencing of microRNAs with the tandem mass spectrometry (MS/MS) mode was discarded due to instrument limitations
dc.format 55 p.
dc.format application/pdf
dc.language eng
dc.rights cc-by-nc-nd (c) Martín, 2019
dc.rights http://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.rights info:eu-repo/semantics/openAccess
dc.source Treballs Finals de Grau (TFG) - Química
dc.subject Electroforesi capil·lar
dc.subject Espectrometria de masses
dc.subject Separació (Tecnologia)
dc.subject Treballs de fi de grau
dc.subject Capillary electrophoresis
dc.subject Mass spectrometry
dc.subject Separation (Technology)
dc.subject Bachelor's theses
dc.title Separation and characterization of microRNAs by capillary electrophoresis with ultraviolet detection and mass spectrometry
dc.title Separació i caracterització de microARNs amb electroforesi capil·lar amb detecció ultraviolada i espectrometria de masses
dc.type info:eu-repo/semantics/bachelorThesis


Fitxers en aquest element

Fitxers Grandària Format Visualització

No hi ha fitxers associats a aquest element.

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a DSpace


Cerca avançada

Visualitza

El meu compte